Analisis Sistem U Tilitas Gedung Oncology RSUP Kandou Manado

Authors

  • Ribka Katuhe Politeknik Negeri Manado
  • Hendrie Joudi Palar Politeknik Negeri Manado
  • Cyntha Tendean Politeknik Negeri Manado

DOI:

https://doi.org/10.58169/jusit.v4i2.1217

Keywords:

Air Conditioning, Elevator, Hospital, Oncology Building, Utilities

Abstract

Utility systems are essential for ensuring safety, comfort, and operational efficiency in hospital buildings. This study aims to analyze the implementation and technical compliance of air conditioning (AC) and elevator systems in the Oncology Building of RSUP Dr. R.D. Kandou Manado. A descriptive-evaluative method combining quantitative and qualitative approaches was employed. Data were collected through field observations, documentation, and technical project documents. The AC system was evaluated based on its type, installation layout, air distribution, and capacity, while the elevator system was assessed in terms of specifications, travel time, waiting time, and handling capacity. The findings indicate that the building utilizes a central AC system with 4-way cassette units installed in spacious rooms and 2-way cassette units in elongated rooms to support appropriate air distribution. However, comprehensive evaluation of AC capacity remains limited by incomplete technical specifications and air parameter measurements. The elevator system consists of two bed lifts and two fire lifts, each with a capacity of 1,800 kg and a speed of 120 meters per minute. The calculated round trip time was 152.4 seconds, while the Elevator Traffic Analysis indicated a waiting time of 41.13 seconds and a handling capacity of 10.89%. These elevator performance indicators met the criteria applied in the study based on SNI 03-6573-2001. The findings provide a basis for evaluating hospital utility systems and identifying areas requiring further technical assessment.

References

Badan Standardisasi Nasional. (2001a). SNI 03-6572-2001: Tata cara perancangan sistem ventilasi dan pengkondisian udara pada bangunan gedung.

Badan Standardisasi Nasional. (2001b). SNI 03-6573-2001: Tata cara perancangan sistem transportasi vertikal dalam gedung (lif).

Badan Standardisasi Nasional. (2011). SNI 6390:2011: Konservasi energi sistem tata udara pada bangunan gedung.

Balaras, C. A., Dascalaki, E., & Gaglia, A. (2007). HVAC and indoor thermal conditions in hospital operating rooms. Energy and Buildings, 39(4), 454–470. https://doi.org/10.1016/j.enbuild.2006.09.004

Chair, S. Y., Ng, S. T., Chao, C. Y. H., & Xu, J. F. (2023). Heating, ventilation, and air-conditioning systems in healthcare: A scoping review. Journal of Hospital Infection, 141, 33–40. https://doi.org/10.1016/j.jhin.2023.08.012

Chu, S. C. K., Lin, C. K. Y., & Lam, S. S. (2003). Hospital lift system simulator: A performance evaluator-predictor. European Journal of Operational Research, 146(1), 156–180. https://doi.org/10.1016/S0377-2217(02)00203-5

Deligöz, D., & Harputlugil, T. (2025). Importance of zoning for vertical circulation planning of densely populated buildings: A simulation-based approach for elevator traffic analyses. Gazi University Journal of Science, 38(4). https://doi.org/10.35378/gujs.1631473

Gatea, A., Mohideen Batcha, M. F., & Taweekun, J. (2020). Energy efficiency and thermal comfort in hospital buildings: A review. International Journal of Integrated Engineering, 12(3), 33–41. https://doi.org/10.30880/ijie.2020.12.03.005

Ibrahim, F., Samsudin, E. Z., Ishak, A. R., & Sathasivam, J. (2022). Hospital indoor air quality and its relationships with building design, building operation, and occupant-related factors: A mini-review. Frontiers in Public Health, 10, Article 1067764. https://doi.org/10.3389/fpubh.2022.1067764

Kementerian Kesehatan Republik Indonesia. (2022). Peraturan Menteri Kesehatan Republik Indonesia Nomor 40 Tahun 2022 tentang persyaratan teknis bangunan, prasarana, dan peralatan kesehatan rumah sakit.

National Fire Protection Association. (2021). NFPA 101: Life safety code.

Santana, E. G. F., Suzuki, E. H., Prado, R. T. A., & Kurokawa, F. A. (2024). Thermal comfort and indoor air quality in hospitals in the subtropics: Analysis of operating rooms and waiting rooms conditions. Indoor and Built Environment, 33(5), 916–928. https://doi.org/10.1177/1420326X231224654

Schroeffer, K. G., & Pagel, É. C. (2025). Indoor air quality in healthcare buildings and ventilation systems. PARC: Pesquisa em Arquitetura e Construção, 16, Article e025007. https://doi.org/10.20396/parc.v16i00.8674496

Shajahan, A., Culp, C. H., & Williamson, B. (2019). Effects of indoor environmental parameters related to building heating, ventilation, and air conditioning systems on patients' medical outcomes: A review of scientific research on hospital buildings. Indoor Air, 29(2), 161–176. https://doi.org/10.1111/ina.12531

Yuan, F., Yao, R., Sadrizadeh, S., Li, B., Cao, G., Zhang, S., Zhou, S., Liu, H., Bogdan, A., Croitoru, C., Melikov, A., Short, C. A., & Li, B. (2022). Thermal comfort in hospital buildings—A literature review. Journal of Building Engineering, 45, Article 103463. https://doi.org/10.1016/j.jobe.2021.103463

Zayadi, A., Cahyono, H. P., & Masyhudi. (2016). Perencanaan lift hotel bertingkat tiga puluh berdasarkan SNI Nomor 03-6573-2001. Jurnal Ilmiah GIGA, 19(2), 61–68. https://doi.org/10.47313/jig.v19i2.566

Downloads

Published

2026-11-04

How to Cite

Ribka Katuhe, Hendrie Joudi Palar, & Cyntha Tendean. (2026). Analisis Sistem U Tilitas Gedung Oncology RSUP Kandou Manado. Jurnal Sipil Terapan, 4(2), 28–38. https://doi.org/10.58169/jusit.v4i2.1217

Similar Articles

1 2 3 > >> 

You may also start an advanced similarity search for this article.