The Motor Control Center (MCC) Panel is a collection of components that become the control center in the operation of a three-phase electric motor with a larger capacity used as a clean water distribution pump machine. In this study has several objectives, including namely 1). Knowing the process of the Drinking Water Supply System (SPAM) in Perumdam Tirta Madani Serang City, 2). Knowing the working system of the MCC-300 Panel as a controller for the distribution machine at Perumdam Tirta Madani, Serang City, 3). Knowing how to maintain the MCC-300 Panel and clean water distribution machines at Perumdam Tirta Madani, Serang City. The methods used are observation, interviews, documentation and literature study. Prumdam Tirta Madani Serang City has several components in the clean water supply system, including raw water components, raw water transmission components, production unit components, and distribution unit components. In the working system the MCC-300 Panel consists of two blocks and there are other components contained in the panel. Then maintenance is carried out on the MCC-300 Panel and Distribution Machine, namely planned maintenance starting from cleaning to carrying out tests on components and machines using an electric meter.

References

Apriani, Y. (2021). Analisa Sistem Pengaman Motor Listrik Dengan Menggunakan Maine Control Center (MCC) PT Perta-Samta Gas Sungai Gerong. Fakultas Teknik Universitas Muhammaddiyah Palembang, 45-55.

Bhaskoro, R. G. (2018). Evaluasi Kinerja Instalasi Pengolahan Air Minum (IPAM) Karangpaling 1 PDAM Surya Sembada Kota Surabaya Secara Kuantitatif. Jurnal Presipitasi : Media Komunikasi dan Pengembangan Teknik Lingkungan, 15, 62-68.

Kencanawati, M. (2017). Analisis Pengolahan Air Bersih Pada WTP PDAM Prapatan Kota Balikpapan. Jurnal TRANSUKMA, 2, 103-117.

Martheana Kencanawati, H. (2016). Analisis Sistem Distribusi Air Bersih Berdasarkan Parameter Debit dan Tekanan Air. Jurnal TRANSUKMA, 2, 1-6.

Mayudin, I. A. (2021). Analisis Kualitas Air Baku, Pengolahan, Dan Distribusi PDAM Tirta Al-Bantani Kabupaten Serang. Jurnal Lingkungan dan Sumberdaya Alam (JURNALIS), 4, 142-150.

Murdianto, D. (2016). Pemodelan Instalasi Pengolahan Air Bersih Menggunakan Hybrid Petri Net. Fakultas Matematika dan Ilmu Pengetahuan Alam, 1-14.

Sarjono. (2020). Evaluasi Kinerja Motor Induksi 3 Fasa 100 HP/ 75 KW Pada Panel Star-Delta di PDAM Tirta Raya Adi Sucipto Kubu Raya. Fakultas Teknik Universitas Tanjungpura Pontianak, 1-8.

Downloads

Published

2023-06-09

How to Cite

Yunita Yunita, & Mohammad Fatkhurrokhman. (2023). Panel MCC-300 Sebagai Alat Pengontrol Mesin Pompa Distribusi Air Bersih di Spam Perumdam Tirta Madani Kota Serang. Jurnal Sains Dan Teknologi, 2(1), 1–14. https://doi.org/10.58169/saintek.v2i1.123